{"id":635,"date":"2012-04-18T08:57:39","date_gmt":"2012-04-18T08:57:39","guid":{"rendered":"http:\/\/blog.uk.tdk-lambda.com\/uk\/?p=635"},"modified":"2012-04-13T09:59:29","modified_gmt":"2012-04-13T09:59:29","slug":"minimum-loads-and-cross-regulation-on-multiple-output-power-supplies","status":"publish","type":"post","link":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/","title":{"rendered":"Minimum loads and cross-regulation on multiple output power supplies"},"content":{"rendered":"<p>By Martin Southam, Director of Marketing, TDK-Lambda EMEA<\/p>\n<p>One subject that our Technical Support team gets asked about frequently is minimum loads on multiple output power supplies, so I thought this would be a good subject to write about.<\/p>\n<p>On a low cost, low power, multiple output power supply, the datasheet will often state that to maintain regulation, a minimum load has to be applied to one or more of the outputs.<\/p>\n<p>To explain why, here is a block diagram of one such simple triple output power supply.<\/p>\n<p><a href=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig1.png\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig1-300x235.png\" alt=\"Block Diagram of a Triple Output Power Supply\" width=\"300\" height=\"235\" class=\"aligncenter size-medium wp-image-636\" srcset=\"https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2012\/04\/2012-04-fig1-300x235.png 300w, https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2012\/04\/2012-04-fig1.png 504w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><br \/>\nFig. 1: Block diagram of a triple output power supply<\/p>\n<p>As you can see, on the middle right hand side of the diagram are the three output windings from the transformer. <\/p>\n<p>On Channel 1 (+5V), the output from the transformer is rectified and filtered to provide a smooth, DC output. If that output voltage is not at the set voltage, say due to a load change, the power supply will automatically correct itself. It does this by sensing the output voltage, comparing it to an internal reference, and feeding back a signal to the control circuit via the optocoupler. The control circuit will then adjust the pulse width of the converter accordingly. The regulation on this output is typically 1 to 2%.<\/p>\n<p>On Channels 2 &amp; 3 (+V and \u2013V) though, it can be seen that there is no feed back to the control circuit &#8211; these outputs are referred to as being semi-regulated. If Channel 2\u2019s load were to increase for example, the output would drop slightly, but there would not be any automatic correction. That voltage drop is specified by the load regulation specification, typically 3 to 5%. <\/p>\n<p>With respect to minimum loading, if there is little or no load on Channel 1, the output will still be at the set voltage, but the switching converter pulse width will be very narrow. The output voltage on Channels 2 &amp; 3 drops fairly dramatically at these narrow pulse widths, particularly if the outputs are supplying their full rated load. An output voltage of 12V, for instance, may drop to 8V. Conversely, if the full rated load is applied to Channel 1, but Channels 2 &amp; 3 are not loaded, the voltages on 2 &amp; 3 will rise, and a 12V output could deliver over 14V. <\/p>\n<p>The effect that varying loads on Channel 1 has on the semi-regulated Channels 2 &amp; 3, is many times referred to as the cross regulation specification.<\/p>\n<p>Manufacturers of power supplies specify a minimum load requirement on Channel 1, usually 10%, to warn the user. Minimum loads may also be specified on Channels 2 &amp; 3 to promote a better regulation specification.<\/p>\n<p>Operating without a minimum load will not normally cause a power supply to fail, but can stress the user\u2019s equipment.<\/p>\n<p>Some power supplies, such as the TDK-Lambda <a title=\"MTW series\" href=\"https:\/\/www.emea.lambda.tdk.com\/uk\/public\/product_details.aspx?cid=1&amp;t1type=acdc&amp;scid=208\" target=\"_blank\">MTW series<\/a>, employ two converters to improve power supply regulation &#8211; one to supply Channel 1 and another to supply Channels 2 &amp; 3.<br \/>\nNote: Both V2 and V3 are sensed by the control circuit.<\/p>\n<p><a href=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig2.png\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig2-300x144.png\" alt=\"TDK-Lambda MTW series power supply features two converters\" width=\"300\" height=\"144\" class=\"aligncenter size-medium wp-image-637\" srcset=\"https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2012\/04\/2012-04-fig2-300x144.png 300w, https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2012\/04\/2012-04-fig2.png 792w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><br \/>\nFig. 2: TDK-Lambda MTW series power supply features two converters<\/p>\n<p>Other products, such as the TDK-Lambda <a title=\"NV175 series\" href=\"https:\/\/www.emea.lambda.tdk.com\/uk\/nv\" target=\"_blank\">NV175 series<\/a> employ post regulators on each output, completely eliminating the minimum load requirement. Although this does add cost to the power supply, it removes any concern for the user and helps with system flexibility. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>By Martin Southam, Director of Marketing, TDK-Lambda EMEA One subject that our Technical Support team gets asked about frequently is minimum loads on multiple output power supplies, so I thought this would be a good subject to write about. On a low cost, low power, multiple output power supply, the datasheet will often state that [&hellip;]<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-635","post","type-post","status-publish","format-standard","hentry","category-power-supply-basics"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Minimum loads and cross-regulation on multiple output power supplies &#171; TDK-Lambda UK Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Minimum loads and cross-regulation on multiple output power supplies &#171; TDK-Lambda UK Blog\" \/>\n<meta property=\"og:description\" content=\"By Martin Southam, Director of Marketing, TDK-Lambda EMEA One subject that our Technical Support team gets asked about frequently is minimum loads on multiple output power supplies, so I thought this would be a good subject to write about. On a low cost, low power, multiple output power supply, the datasheet will often state that [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/\" \/>\n<meta property=\"og:site_name\" content=\"TDK-Lambda UK Blog\" \/>\n<meta property=\"article:published_time\" content=\"2012-04-18T08:57:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig1-300x235.png\" \/>\n<meta name=\"author\" content=\"Dulcie\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dulcie\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/\"},\"author\":{\"name\":\"Dulcie\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/a0eecfbb93bfb5281b703bd45b29d4eb\"},\"headline\":\"Minimum loads and cross-regulation on multiple output power supplies\",\"datePublished\":\"2012-04-18T08:57:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/\"},\"wordCount\":541,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/files\\\/2012\\\/04\\\/2012-04-fig1-300x235.png\",\"articleSection\":[\"Power Supply Basics\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/\",\"name\":\"Minimum loads and cross-regulation on multiple output power supplies &#171; TDK-Lambda UK Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/files\\\/2012\\\/04\\\/2012-04-fig1-300x235.png\",\"datePublished\":\"2012-04-18T08:57:39+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/a0eecfbb93bfb5281b703bd45b29d4eb\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/files\\\/2012\\\/04\\\/2012-04-fig1.png\",\"contentUrl\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/files\\\/2012\\\/04\\\/2012-04-fig1.png\",\"width\":\"504\",\"height\":\"396\",\"caption\":\"Block Diagram of a Triple Output Power Supply\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2012\\\/04\\\/18\\\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Minimum loads and cross-regulation on multiple output power supplies\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#website\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/\",\"name\":\"TDK-Lambda UK Blog\",\"description\":\"TDK-Lambda EMEA Power Supply News\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/a0eecfbb93bfb5281b703bd45b29d4eb\",\"name\":\"Dulcie\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g\",\"caption\":\"Dulcie\"},\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/author\\\/dulcie\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Minimum loads and cross-regulation on multiple output power supplies &#171; TDK-Lambda UK Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/","og_locale":"en_GB","og_type":"article","og_title":"Minimum loads and cross-regulation on multiple output power supplies &#171; TDK-Lambda UK Blog","og_description":"By Martin Southam, Director of Marketing, TDK-Lambda EMEA One subject that our Technical Support team gets asked about frequently is minimum loads on multiple output power supplies, so I thought this would be a good subject to write about. On a low cost, low power, multiple output power supply, the datasheet will often state that [&hellip;]","og_url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/","og_site_name":"TDK-Lambda UK Blog","article_published_time":"2012-04-18T08:57:39+00:00","og_image":[{"url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig1-300x235.png","type":"","width":"","height":""}],"author":"Dulcie","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Dulcie","Estimated reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/#article","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/"},"author":{"name":"Dulcie","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/a0eecfbb93bfb5281b703bd45b29d4eb"},"headline":"Minimum loads and cross-regulation on multiple output power supplies","datePublished":"2012-04-18T08:57:39+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/"},"wordCount":541,"commentCount":0,"image":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig1-300x235.png","articleSection":["Power Supply Basics"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/","name":"Minimum loads and cross-regulation on multiple output power supplies &#171; TDK-Lambda UK Blog","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/#primaryimage"},"image":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig1-300x235.png","datePublished":"2012-04-18T08:57:39+00:00","author":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/a0eecfbb93bfb5281b703bd45b29d4eb"},"breadcrumb":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/#primaryimage","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig1.png","contentUrl":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2012\/04\/2012-04-fig1.png","width":"504","height":"396","caption":"Block Diagram of a Triple Output Power Supply"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2012\/04\/18\/minimum-loads-and-cross-regulation-on-multiple-output-power-supplies\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.uk.tdk-lambda.com\/uk\/"},{"@type":"ListItem","position":2,"name":"Minimum loads and cross-regulation on multiple output power supplies"}]},{"@type":"WebSite","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/","name":"TDK-Lambda UK Blog","description":"TDK-Lambda EMEA Power Supply News","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.uk.tdk-lambda.com\/uk\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/a0eecfbb93bfb5281b703bd45b29d4eb","name":"Dulcie","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g","caption":"Dulcie"},"url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/author\/dulcie\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/635","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/comments?post=635"}],"version-history":[{"count":0,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/635\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/media?parent=635"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/categories?post=635"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/tags?post=635"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}