{"id":5952,"date":"2023-11-28T10:30:51","date_gmt":"2023-11-28T10:30:51","guid":{"rendered":"https:\/\/blog.uk.tdk-lambda.com\/uk\/?p=5952"},"modified":"2023-11-30T18:14:47","modified_gmt":"2023-11-30T18:14:47","slug":"2040w-12v-model-added-to-the-tps-series","status":"publish","type":"post","link":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/","title":{"rendered":"2040W 12V model added to the TPS series"},"content":{"rendered":"<p><span style=\"font-weight: 400\">The TPS4000-12 power supply extends the TPS series of 350 &#8211; 528Vac three-phase input power supplies to include a 12V output in addition to the existing 24V and 48V models.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The series is fully featured with isolated AC Fail, DC Good and dropped phase signals, remote on\/off, remote sense and a 12V 0.3A standby supply. A PMBus\u2122 communications interface allows remote monitoring of the output voltage, output current, internal temperature, status signals and fan speed. In addition, the output voltage, over current limit and the remote on\/off can be programmed using the PMBus.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Up to eight units can be connected in parallel for higher power and internal ORing FETs allow redundant operation. The TPS4000-12 can operate at full load in ambient temperatures of up to 50<\/span><span style=\"font-weight: 400\">o<\/span><span style=\"font-weight: 400\">C and deliver up to 55% load at 70<\/span><span style=\"font-weight: 400\">o<\/span><span style=\"font-weight: 400\">C. Cooling is provided by an internal temperature-controlled fan to reduce acoustical noise. The case measures 107 x 84.4 x 335mm, making it suitable for 2U high racking systems. The weight of the product is 4kg.<\/span><\/p>\n<p><span style=\"font-weight: 400\">All TPS models are certified to IEC\/EN\/UL\/CSA 62368-1 and carry the CE and UKCA marks for the Low Voltage, EMC and RoHS Directives.<\/span><\/p>\n<p><span style=\"font-weight: 400\">For more information about the TDK-Lambda TPS AC-DC power supplies, please visit: <\/span><a href=\"https:\/\/www.emea.lambda.tdk.com\/uk\/products\/tps?utm_source=emea_vanity_url&amp;utm_medium=redirect&amp;utm_campaign=tps\"><span style=\"font-weight: 400\">www.emea.lambda.tdk.com\/<\/span><span style=\"font-weight: 400\">tps<\/span><\/a><\/p>\n<p><span style=\"font-weight: 400\">If you have a question you\u2019d like to ask TDK-Lambda, please feel free to use the <\/span><a href=\"https:\/\/www.emea.lambda.tdk.com\/uk\/support\/product-support\/\"><span style=\"font-weight: 400\">online FAQ form<\/span><\/a><span style=\"font-weight: 400\">, and we\u2019ll get back to you with an answer as soon as possible.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The TPS4000-12 power supply extends the TPS series of 350 &#8211; 528Vac three-phase input power supplies to include a 12V output in addition to the existing 24V and 48V models. The series is fully featured with isolated AC Fail, DC Good and dropped phase signals, remote on\/off, remote sense and a 12V 0.3A standby supply. [&hellip;]<\/p>\n","protected":false},"author":17,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[22,119],"tags":[95],"class_list":["post-5952","post","type-post","status-publish","format-standard","hentry","category-products","category-tps","tag-videos"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>2040W 12V model added to the TPS series<\/title>\n<meta name=\"description\" content=\"The TPS power supply series extends to include a 12V output, the TPS4000-12, in addition to the existing 24V and 48V models.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"2040W 12V model added to the TPS series\" \/>\n<meta property=\"og:description\" content=\"The TPS power supply series extends to include a 12V output, the TPS4000-12, in addition to the existing 24V and 48V models.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/\" \/>\n<meta property=\"og:site_name\" content=\"TDK-Lambda UK Blog\" \/>\n<meta property=\"article:published_time\" content=\"2023-11-28T10:30:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-30T18:14:47+00:00\" \/>\n<meta name=\"author\" content=\"David\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"David\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/\"},\"author\":{\"name\":\"David\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/bef16e57e41b757a81229141a95d6853\"},\"headline\":\"2040W 12V model added to the TPS series\",\"datePublished\":\"2023-11-28T10:30:51+00:00\",\"dateModified\":\"2023-11-30T18:14:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/\"},\"wordCount\":257,\"commentCount\":0,\"keywords\":[\"Videos\"],\"articleSection\":[\"Products\",\"TPS\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/\",\"name\":\"2040W 12V model added to the TPS series\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#website\"},\"datePublished\":\"2023-11-28T10:30:51+00:00\",\"dateModified\":\"2023-11-30T18:14:47+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/bef16e57e41b757a81229141a95d6853\"},\"description\":\"The TPS power supply series extends to include a 12V output, the TPS4000-12, in addition to the existing 24V and 48V models.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2023\\\/11\\\/28\\\/2040w-12v-model-added-to-the-tps-series\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"2040W 12V model added to the TPS series\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#website\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/\",\"name\":\"TDK-Lambda UK Blog\",\"description\":\"TDK-Lambda EMEA Power Supply News\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/bef16e57e41b757a81229141a95d6853\",\"name\":\"David\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g\",\"caption\":\"David\"},\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/author\\\/dummyacc04\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"2040W 12V model added to the TPS series","description":"The TPS power supply series extends to include a 12V output, the TPS4000-12, in addition to the existing 24V and 48V models.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/","og_locale":"en_GB","og_type":"article","og_title":"2040W 12V model added to the TPS series","og_description":"The TPS power supply series extends to include a 12V output, the TPS4000-12, in addition to the existing 24V and 48V models.","og_url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/","og_site_name":"TDK-Lambda UK Blog","article_published_time":"2023-11-28T10:30:51+00:00","article_modified_time":"2023-11-30T18:14:47+00:00","author":"David","twitter_card":"summary_large_image","twitter_misc":{"Written by":"David","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/#article","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/"},"author":{"name":"David","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/bef16e57e41b757a81229141a95d6853"},"headline":"2040W 12V model added to the TPS series","datePublished":"2023-11-28T10:30:51+00:00","dateModified":"2023-11-30T18:14:47+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/"},"wordCount":257,"commentCount":0,"keywords":["Videos"],"articleSection":["Products","TPS"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/","name":"2040W 12V model added to the TPS series","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website"},"datePublished":"2023-11-28T10:30:51+00:00","dateModified":"2023-11-30T18:14:47+00:00","author":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/bef16e57e41b757a81229141a95d6853"},"description":"The TPS power supply series extends to include a 12V output, the TPS4000-12, in addition to the existing 24V and 48V models.","breadcrumb":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2023\/11\/28\/2040w-12v-model-added-to-the-tps-series\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.uk.tdk-lambda.com\/uk\/"},{"@type":"ListItem","position":2,"name":"2040W 12V model added to the TPS series"}]},{"@type":"WebSite","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/","name":"TDK-Lambda UK Blog","description":"TDK-Lambda EMEA Power Supply News","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.uk.tdk-lambda.com\/uk\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/bef16e57e41b757a81229141a95d6853","name":"David","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g","caption":"David"},"url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/author\/dummyacc04\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/5952","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/comments?post=5952"}],"version-history":[{"count":0,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/5952\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/media?parent=5952"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/categories?post=5952"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/tags?post=5952"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}