{"id":5643,"date":"2021-09-10T09:55:09","date_gmt":"2021-09-10T09:55:09","guid":{"rendered":"https:\/\/blog.uk.tdk-lambda.com\/uk\/?p=5643"},"modified":"2021-09-10T09:55:09","modified_gmt":"2021-09-10T09:55:09","slug":"introducing-the-cus350mp-range-of-350-500w-medical-power-supplies","status":"publish","type":"post","link":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/","title":{"rendered":"Introducing the CUS350MP range of 350\/500W medical power supplies"},"content":{"rendered":"<p>The CUS350MP series of \u00a0<a href=\"http:\/\/www.emea.lambda.tdk.com\/cus350mp\">CUS350MP series of power supplies<\/a> are certified to IEC60601-1 3rd edition (medical), IEC62368-1 and IEC62477-1 (OVCIII) with compliance to the EN60601-1-2:2015 Edition 4 immunity requirements. The units also comply with EN 55011-B and EN 55032-B conducted and radiated emissions, meet the EN 61000-3-2 harmonics, IEC60601-1-2:2015 Ed 4 and IEC 61000-4 immunity standards.<\/p>\n<p>The CUS350MP series is rated at 350W continuous and 1000W peak power output with convection cooling for low audible noise applications requiring occasional high peak power demands. With forced-air cooling, the units are rated at 500W continuous and 1000W peak power output. The high peak power rating makes them suitable for use in applications often served by larger, more expensive, non-peak capable power supplies, such as printers and other equipment using DC motors.<\/p>\n<p>Typical application areas are varied and include:<\/p>\n<ul>\n<li>robotics and factory automation<\/li>\n<li>printing and ticketing equipment<\/li>\n<li>hospital, clinical and healthcare equipment<\/li>\n<li>Ultrasound<\/li>\n<li>Dialysis<\/li>\n<li>Bio-diagnostics<\/li>\n<li>Laboratory equipment<\/li>\n<\/ul>\n<p>The CUS350MP series accepts an 85 to 265Vac input and has a leakage current of less than 300\u00b5A. Four output voltages are available: 24, 30, 36 and 48V. A 5V (0.3A) standby voltage and remote on\/off are fitted as standard.<\/p>\n<p>For more information about the <a href=\"https:\/\/www.emea.lambda.tdk.com\/uk\/about\/local-video\/5192\">CUS350MP series<\/a>, please visit: <a href=\"http:\/\/www.emea.lambda.tdk.com\/cus350mp\">www.emea.lambda.tdk.com\/cus350mp<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The CUS350MP series of \u00a0CUS350MP series of power supplies are certified to IEC60601-1 3rd edition (medical), IEC62368-1 and IEC62477-1 (OVCIII) with compliance to the EN60601-1-2:2015 Edition 4 immunity requirements. The units also comply with EN 55011-B and EN 55032-B conducted and radiated emissions, meet the EN 61000-3-2 harmonics, IEC60601-1-2:2015 Ed 4 and IEC 61000-4 immunity [&hellip;]<\/p>\n","protected":false},"author":17,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[41,22],"tags":[95],"class_list":["post-5643","post","type-post","status-publish","format-standard","hentry","category-cus","category-products","tag-videos"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Introducing the CUS350MP range of 350\/500W medical power supplies<\/title>\n<meta name=\"description\" content=\"The CUS350MP series is rated at 350W continuous and 1000W peak power output with convection cooling for low audible noise applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Introducing the CUS350MP range of 350\/500W medical power supplies\" \/>\n<meta property=\"og:description\" content=\"The CUS350MP series is rated at 350W continuous and 1000W peak power output with convection cooling for low audible noise applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/\" \/>\n<meta property=\"og:site_name\" content=\"TDK-Lambda UK Blog\" \/>\n<meta property=\"article:published_time\" content=\"2021-09-10T09:55:09+00:00\" \/>\n<meta name=\"author\" content=\"David\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"David\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/\"},\"author\":{\"name\":\"David\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/6a80da7b9fb74507fcb8c2bd38ee0dac\"},\"headline\":\"Introducing the CUS350MP range of 350\\\/500W medical power supplies\",\"datePublished\":\"2021-09-10T09:55:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/\"},\"wordCount\":228,\"commentCount\":0,\"keywords\":[\"Videos\"],\"articleSection\":[\"CUS\",\"Products\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/\",\"name\":\"Introducing the CUS350MP range of 350\\\/500W medical power supplies\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#website\"},\"datePublished\":\"2021-09-10T09:55:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/6a80da7b9fb74507fcb8c2bd38ee0dac\"},\"description\":\"The CUS350MP series is rated at 350W continuous and 1000W peak power output with convection cooling for low audible noise applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2021\\\/09\\\/10\\\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Introducing the CUS350MP range of 350\\\/500W medical power supplies\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#website\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/\",\"name\":\"TDK-Lambda UK Blog\",\"description\":\"TDK-Lambda EMEA Power Supply News\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/6a80da7b9fb74507fcb8c2bd38ee0dac\",\"name\":\"David\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g\",\"caption\":\"David\"},\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/author\\\/dummyacc04\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Introducing the CUS350MP range of 350\/500W medical power supplies","description":"The CUS350MP series is rated at 350W continuous and 1000W peak power output with convection cooling for low audible noise applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/","og_locale":"en_GB","og_type":"article","og_title":"Introducing the CUS350MP range of 350\/500W medical power supplies","og_description":"The CUS350MP series is rated at 350W continuous and 1000W peak power output with convection cooling for low audible noise applications.","og_url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/","og_site_name":"TDK-Lambda UK Blog","article_published_time":"2021-09-10T09:55:09+00:00","author":"David","twitter_card":"summary_large_image","twitter_misc":{"Written by":"David","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/#article","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/"},"author":{"name":"David","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/6a80da7b9fb74507fcb8c2bd38ee0dac"},"headline":"Introducing the CUS350MP range of 350\/500W medical power supplies","datePublished":"2021-09-10T09:55:09+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/"},"wordCount":228,"commentCount":0,"keywords":["Videos"],"articleSection":["CUS","Products"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/","name":"Introducing the CUS350MP range of 350\/500W medical power supplies","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website"},"datePublished":"2021-09-10T09:55:09+00:00","author":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/6a80da7b9fb74507fcb8c2bd38ee0dac"},"description":"The CUS350MP series is rated at 350W continuous and 1000W peak power output with convection cooling for low audible noise applications.","breadcrumb":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2021\/09\/10\/introducing-the-cus350mp-range-of-350-500w-medical-power-supplies\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.uk.tdk-lambda.com\/uk\/"},{"@type":"ListItem","position":2,"name":"Introducing the CUS350MP range of 350\/500W medical power supplies"}]},{"@type":"WebSite","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/","name":"TDK-Lambda UK Blog","description":"TDK-Lambda EMEA Power Supply News","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.uk.tdk-lambda.com\/uk\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/6a80da7b9fb74507fcb8c2bd38ee0dac","name":"David","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/75c7846acedd957aead8e3938a8acce1fd6aa8501b53d728d7baae6e5e52bb4c?s=96&d=mm&r=g","caption":"David"},"url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/author\/dummyacc04\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/5643","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/comments?post=5643"}],"version-history":[{"count":0,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/5643\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/media?parent=5643"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/categories?post=5643"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/tags?post=5643"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}