{"id":5380,"date":"2020-07-09T08:01:14","date_gmt":"2020-07-09T08:01:14","guid":{"rendered":"https:\/\/blog.uk.tdk-lambda.com\/uk\/?p=5380"},"modified":"2020-07-09T08:14:08","modified_gmt":"2020-07-09T08:14:08","slug":"how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating","status":"publish","type":"post","link":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/","title":{"rendered":"How to ensure reliable operation of DC-DC converters (cooling and derating)"},"content":{"rendered":"\n<p>Today\u2019s manufacturing techniques have improved DC-DC reliability considerably. The use of surface-mount placement for 100% of the components, computerised optical inspection of solder joints, automated test and laser marking has eliminated most of the manual tasks. Production for <a href=\"https:\/\/www.emea.lambda.tdk.com\/cc-e\">TDK\u2011Lambda\u2019s CC-E series of DC-DC converters<\/a> has even recently deployed double-armed robots to form the converter leads, attach metal EMI shielding covers and package the final product into trays. Reflecting this, many DC-DC converter manufacturers offer five-year warranties.<\/p>\n\n\n\n<p>Internally, ceramic capacitors have replaced electrolytic capacitors that age as their electrolyte dries out. Consequently, <a href=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/02\/20\/mtbf-is-it-a-prediction-of-a-power-supplys-operating-life\/\">Mean Time Between Failure (MTBF) calculations<\/a> are correspondingly higher. <a href=\"https:\/\/www.emea.lambda.tdk.com\/ccg\">TDK-Lambda\u2019s CCG15 series of 15W converters<\/a> have calculated MTBF numbers, using the Telcordia reliability prediction procedure, of millions of hours. The number varies with temperature and output load, as component reliability reduces as temperature rises. See Figure 1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1029\" height=\"491\" src=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg\" alt=\"\" class=\"wp-image-5381\" srcset=\"https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b1.jpg 1029w, https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b1-300x143.jpg 300w, https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b1-1024x489.jpg 1024w, https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b1-768x366.jpg 768w\" sizes=\"auto, (max-width: 1029px) 100vw, 1029px\" \/><figcaption>Figure 1: MTBF versus ambient temperature for the CCG15-48-S12 converter<\/figcaption><\/figure>\n\n\n\n<p>To ensure high reliability and long field life, the user must ensure that the DC-DC converter operates as cool as possible in the end equipment. Some initial work should be performed before the design of the printed circuit board starts.<\/p>\n\n\n\n<p><span style=\"text-decoration: underline\">Power budget and derating<\/span><\/p>\n\n\n\n<p>Most engineers will develop a \u2018power budget\u2019, estimating how much current will be needed for their load. As an example, we will use a budget of 12V 0.8A = 9.6W.<\/p>\n\n\n\n<p>It is strongly advised never to operate any DC-DC converter or power supply at its maximum ratings. Derating will increase the field life of the end equipment and provide some margin if the actual power estimate comes over budget. A figure of 50% to 75% is widely used in the electronics industry. With this in mind, we will select a 15W converter and operate it at 63% load. The CCG15-48-S12 can deliver 12V 1.3A with an input voltage of 18 to 76V and we will use this product in our example.<\/p>\n\n\n\n<p><span style=\"text-decoration: underline\">Ambient temperature<\/span><\/p>\n\n\n\n<p>The ambient temperature <em>inside<\/em> the system or enclosure can be calculated, estimated or measured. If the application is a convection cooled, bench mounted instrument with ventilation slots for example, 40\u00b0C will probably suffice.<\/p>\n\n\n\n<p>We will then use the manufacturer\u2019s datasheet to determine where we are on the derating curves, see Figure 2.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"604\" height=\"435\" src=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b2.jpg\" alt=\"\" class=\"wp-image-5382\" srcset=\"https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b2.jpg 604w, https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b2-300x216.jpg 300w\" sizes=\"auto, (max-width: 604px) 100vw, 604px\" \/><figcaption>Figure 2: Derating information for the CCG15-48-S12 converter<\/figcaption><\/figure>\n\n\n\n<p>In our example, there is no derating required with a convection cooled 40\u00b0C ambient at 63% load. Even if the ambient temperature rose to 75\u00b0C, due to an abnormal situation, there is sufficient margin.<\/p>\n\n\n\n<p><span style=\"text-decoration: underline\">Airflow within the enclosure<\/span><\/p>\n\n\n\n<p>When \u2018natural convection\u2019 is indicated on a derating curve, it does not mean zero airflow. As heat rises, there will be some (natural) air movement which will cool the converter. During the design of the printed circuit board, avoid large components impeding that natural airflow.<\/p>\n\n\n\n<p><span style=\"text-decoration: underline\">Testing<\/span><\/p>\n\n\n\n<p>When testing your prototype system or equipment, measure the case temperature of the DC-DC converter and the ambient temperature to confirm the initial estimates and \/ or calculations.<\/p>\n\n\n\n<p>Manufacturers will state which points that should be measured and where. In our example, the CCG converters are measured in the middle of the case. Figure 3, and typically 76mm away from the side of the converter (Figure 4), to avoid measuring the hot air rising from the case.<\/p>\n\n\n\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"280\" src=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b3-300x280.jpg\" alt=\"\" class=\"wp-image-5383\" srcset=\"https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b3-300x280.jpg 300w, https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b3.jpg 413w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption>Figure 3: Measurement location for case temperature<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"761\" height=\"314\" src=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b4.jpg\" alt=\"\" class=\"wp-image-5384\" srcset=\"https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b4.jpg 761w, https:\/\/tdklambdablog.wpenginepowered.com\/uk\/files\/2020\/07\/b4-300x124.jpg 300w\" sizes=\"auto, (max-width: 761px) 100vw, 761px\" \/><figcaption>Figure 4: Measurement of ambient temperature<\/figcaption><\/figure>\n\n\n\n<p>Looking at Figure 1 again, we can see the MTBF number will be between 5M and 6M hours.<\/p>\n\n\n\n<p>Most manufacturers, like <a href=\"https:\/\/www.emea.lambda.tdk.com\/uk\/products\/dcdc-converters\/\">TDK-Lambda, provide detailed on-line information for their products<\/a>, as demonstrated in this article. <a href=\"https:\/\/www.emea.lambda.tdk.com\/uk\/support\/\">Support is also available from experienced staff members<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Today\u2019s manufacturing techniques have improved DC-DC reliability considerably. The use of surface-mount placement for 100% of the components, computerised optical inspection of solder joints, automated test and laser marking has eliminated most of the manual tasks. Production for TDK\u2011Lambda\u2019s CC-E series of DC-DC converters has even recently deployed double-armed robots to form the converter leads, [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[50,1,22],"tags":[],"class_list":["post-5380","post","type-post","status-publish","format-standard","hentry","category-cc-e","category-power-supply-basics","category-products"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to ensure reliable operation of DC-DC converters<\/title>\n<meta name=\"description\" content=\"This article looks at ways to achieve reliable operation of DC-DC converters, covering topics such as cooling and derating.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to ensure reliable operation of DC-DC converters\" \/>\n<meta property=\"og:description\" content=\"This article looks at ways to achieve reliable operation of DC-DC converters, covering topics such as cooling and derating.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/\" \/>\n<meta property=\"og:site_name\" content=\"TDK-Lambda UK Blog\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-09T08:01:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-09T08:14:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg\" \/>\n<meta name=\"author\" content=\"Martin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Martin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/\"},\"author\":{\"name\":\"Martin\",\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/fed179538fc02d371b380786926a5095\"},\"headline\":\"How to ensure reliable operation of DC-DC converters (cooling and derating)\",\"datePublished\":\"2020-07-09T08:01:14+00:00\",\"dateModified\":\"2020-07-09T08:14:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/\"},\"wordCount\":596,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg\",\"articleSection\":[\"CC-E\",\"Power Supply Basics\",\"Products\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/\",\"url\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/\",\"name\":\"How to ensure reliable operation of DC-DC converters\",\"isPartOf\":{\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg\",\"datePublished\":\"2020-07-09T08:01:14+00:00\",\"dateModified\":\"2020-07-09T08:14:08+00:00\",\"author\":{\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/fed179538fc02d371b380786926a5095\"},\"description\":\"This article looks at ways to achieve reliable operation of DC-DC converters, covering topics such as cooling and derating.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#primaryimage\",\"url\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg\",\"contentUrl\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg\",\"width\":1029,\"height\":491},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to ensure reliable operation of DC-DC converters (cooling and derating)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website\",\"url\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/\",\"name\":\"TDK-Lambda UK Blog\",\"description\":\"TDK-Lambda EMEA Power Supply News\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/fed179538fc02d371b380786926a5095\",\"name\":\"Martin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/2e1621406d4b5f8cbbb63de8b89774d92b1d23f8204d4605e75dc6599e961bcb?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/2e1621406d4b5f8cbbb63de8b89774d92b1d23f8204d4605e75dc6599e961bcb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/2e1621406d4b5f8cbbb63de8b89774d92b1d23f8204d4605e75dc6599e961bcb?s=96&d=mm&r=g\",\"caption\":\"Martin\"},\"url\":\"https:\/\/blog.uk.tdk-lambda.com\/uk\/author\/martin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to ensure reliable operation of DC-DC converters","description":"This article looks at ways to achieve reliable operation of DC-DC converters, covering topics such as cooling and derating.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/","og_locale":"en_GB","og_type":"article","og_title":"How to ensure reliable operation of DC-DC converters","og_description":"This article looks at ways to achieve reliable operation of DC-DC converters, covering topics such as cooling and derating.","og_url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/","og_site_name":"TDK-Lambda UK Blog","article_published_time":"2020-07-09T08:01:14+00:00","article_modified_time":"2020-07-09T08:14:08+00:00","og_image":[{"url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg","type":"","width":"","height":""}],"author":"Martin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Martin","Estimated reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#article","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/"},"author":{"name":"Martin","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/fed179538fc02d371b380786926a5095"},"headline":"How to ensure reliable operation of DC-DC converters (cooling and derating)","datePublished":"2020-07-09T08:01:14+00:00","dateModified":"2020-07-09T08:14:08+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/"},"wordCount":596,"commentCount":0,"image":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg","articleSection":["CC-E","Power Supply Basics","Products"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/","name":"How to ensure reliable operation of DC-DC converters","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#primaryimage"},"image":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg","datePublished":"2020-07-09T08:01:14+00:00","dateModified":"2020-07-09T08:14:08+00:00","author":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/fed179538fc02d371b380786926a5095"},"description":"This article looks at ways to achieve reliable operation of DC-DC converters, covering topics such as cooling and derating.","breadcrumb":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#primaryimage","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg","contentUrl":"https:\/\/blog.uk.tdk-lambda.com\/uk\/files\/2020\/07\/b1.jpg","width":1029,"height":491},{"@type":"BreadcrumbList","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2020\/07\/09\/how-to-ensure-reliable-operation-of-dc-dc-converters-cooling-and-derating\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.uk.tdk-lambda.com\/uk\/"},{"@type":"ListItem","position":2,"name":"How to ensure reliable operation of DC-DC converters (cooling and derating)"}]},{"@type":"WebSite","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/","name":"TDK-Lambda UK Blog","description":"TDK-Lambda EMEA Power Supply News","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.uk.tdk-lambda.com\/uk\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/fed179538fc02d371b380786926a5095","name":"Martin","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/2e1621406d4b5f8cbbb63de8b89774d92b1d23f8204d4605e75dc6599e961bcb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2e1621406d4b5f8cbbb63de8b89774d92b1d23f8204d4605e75dc6599e961bcb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2e1621406d4b5f8cbbb63de8b89774d92b1d23f8204d4605e75dc6599e961bcb?s=96&d=mm&r=g","caption":"Martin"},"url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/author\/martin\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/5380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/comments?post=5380"}],"version-history":[{"count":0,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/5380\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/media?parent=5380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/categories?post=5380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/tags?post=5380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}