{"id":3113,"date":"2015-10-06T07:00:21","date_gmt":"2015-10-06T07:00:21","guid":{"rendered":"http:\/\/blog.uk.tdk-lambda.com\/uk\/?p=3113"},"modified":"2015-10-06T07:26:45","modified_gmt":"2015-10-06T07:26:45","slug":"ieculen-60950-1-amendment-2","status":"publish","type":"post","link":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/","title":{"rendered":"IEC\/UL\/EN 60950-1 Amendment 2"},"content":{"rendered":"<p>In August 2013, CENELEC published Amendment 2 to EN 60950-1:2006 covering the general safety requirements of ITE (Information Technology Equipment). July 2nd, 2016 is the expiry date for Amendment 1 of EN 60950-1, and manufacturers are working through their 60950-1 reports to update their files.<\/p>\n<p>For Europe, this amends EN 60950-1:2006 and its Amendments 1 and 12. Safety files will now state EN 60950-1:2006\/A2:2013 or EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013. It has been widely stated that this will be the last change to the 60950-1 standard.<\/p>\n<p>Oct 14, 2014 was the publication date by UL and CSA for the update to UL\/CSA 60950-1 and safety files will now refer to UL 60950-1, 2nd Edition, 2014-10-14 and CAN\/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10. In UL\/CSA\u2019s case, upgrading to Amendment 2 is not mandatory on existing product files.<\/p>\n<p>With the upcoming June 2019 transition to IEC 62368-1:2014 for both IEC 60950-1 and IEC 60065, what was changed? Fortunately for the power supply manufacturers, the changes to IEC 60950-1 are mainly \u201cclarifications\u201d. Both T\u00dcV Rheinland\u00ae and UL reported that in general there would be no impact requiring product changes and\/or that it was reflecting their current practice.<\/p>\n<p>For IEC 60950-1 the main changes for power supplies are:<\/p>\n<ul>\n<li>Clause 1.7.1.3 requires that any graphics used are to comply with ISO standards and should be explained in the manual. These include some (not widely used) earth grounding symbols.<\/li>\n<li>Clause 2.9.2 introduced humidity testing to equipment designated for tropical regions. Chinese CCC and CQC safety standards have been concerned about this for some time.<\/li>\n<li>Likewise 2.10.3 refers to a common requirement in China for a higher maximum altitude, typically 5,000m, or the addition of a symbol indicating operation at a maximum of 2,000m. This is not an issue for UL, EN or CB.<\/li>\n<li>Clause 4.3.8 requires non lead acid batteries to comply with IEC 62133, with the exception of button style batteries. This will only affect a very limited number of power supplies.<\/li>\n<li>The use of VDRs (voltage dependant resistors), which was a major change for Edition 1, have had a flammability requirement added.<\/li>\n<\/ul>\n<p>Indeed this amendment is widely seen by the safety bodies as a way to ensure a smoother transition into IEC 62368-1:2014.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In August 2013, CENELEC published Amendment 2 to EN 60950-1:2006 covering the general safety requirements of ITE (Information Technology Equipment). July 2nd, 2016 is the expiry date for Amendment 1 of EN 60950-1, and manufacturers are working through their 60950-1 reports to update their files. For Europe, this amends EN 60950-1:2006 and its Amendments 1 [&hellip;]<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3113","post","type-post","status-publish","format-standard","hentry","category-power-supply-basics"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>IEC\/UL\/EN 60950-1 Amendment 2 &#171; TDK-Lambda UK Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IEC\/UL\/EN 60950-1 Amendment 2 &#171; TDK-Lambda UK Blog\" \/>\n<meta property=\"og:description\" content=\"In August 2013, CENELEC published Amendment 2 to EN 60950-1:2006 covering the general safety requirements of ITE (Information Technology Equipment). July 2nd, 2016 is the expiry date for Amendment 1 of EN 60950-1, and manufacturers are working through their 60950-1 reports to update their files. For Europe, this amends EN 60950-1:2006 and its Amendments 1 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/\" \/>\n<meta property=\"og:site_name\" content=\"TDK-Lambda UK Blog\" \/>\n<meta property=\"article:published_time\" content=\"2015-10-06T07:00:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2015-10-06T07:26:45+00:00\" \/>\n<meta name=\"author\" content=\"Dulcie\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dulcie\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/\"},\"author\":{\"name\":\"Dulcie\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/bb64053c3efbdc9d39bbb581db1af6bd\"},\"headline\":\"IEC\\\/UL\\\/EN 60950-1 Amendment 2\",\"datePublished\":\"2015-10-06T07:00:21+00:00\",\"dateModified\":\"2015-10-06T07:26:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/\"},\"wordCount\":368,\"commentCount\":0,\"articleSection\":[\"Power Supply Basics\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/\",\"name\":\"IEC\\\/UL\\\/EN 60950-1 Amendment 2 &#171; TDK-Lambda UK Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#website\"},\"datePublished\":\"2015-10-06T07:00:21+00:00\",\"dateModified\":\"2015-10-06T07:26:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/bb64053c3efbdc9d39bbb581db1af6bd\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/2015\\\/10\\\/06\\\/ieculen-60950-1-amendment-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IEC\\\/UL\\\/EN 60950-1 Amendment 2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#website\",\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/\",\"name\":\"TDK-Lambda UK Blog\",\"description\":\"TDK-Lambda EMEA Power Supply News\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/#\\\/schema\\\/person\\\/bb64053c3efbdc9d39bbb581db1af6bd\",\"name\":\"Dulcie\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g\",\"caption\":\"Dulcie\"},\"url\":\"https:\\\/\\\/blog.uk.tdk-lambda.com\\\/uk\\\/author\\\/dulcie\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IEC\/UL\/EN 60950-1 Amendment 2 &#171; TDK-Lambda UK Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/","og_locale":"en_GB","og_type":"article","og_title":"IEC\/UL\/EN 60950-1 Amendment 2 &#171; TDK-Lambda UK Blog","og_description":"In August 2013, CENELEC published Amendment 2 to EN 60950-1:2006 covering the general safety requirements of ITE (Information Technology Equipment). July 2nd, 2016 is the expiry date for Amendment 1 of EN 60950-1, and manufacturers are working through their 60950-1 reports to update their files. For Europe, this amends EN 60950-1:2006 and its Amendments 1 [&hellip;]","og_url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/","og_site_name":"TDK-Lambda UK Blog","article_published_time":"2015-10-06T07:00:21+00:00","article_modified_time":"2015-10-06T07:26:45+00:00","author":"Dulcie","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Dulcie","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/#article","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/"},"author":{"name":"Dulcie","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/bb64053c3efbdc9d39bbb581db1af6bd"},"headline":"IEC\/UL\/EN 60950-1 Amendment 2","datePublished":"2015-10-06T07:00:21+00:00","dateModified":"2015-10-06T07:26:45+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/"},"wordCount":368,"commentCount":0,"articleSection":["Power Supply Basics"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/","name":"IEC\/UL\/EN 60950-1 Amendment 2 &#171; TDK-Lambda UK Blog","isPartOf":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website"},"datePublished":"2015-10-06T07:00:21+00:00","dateModified":"2015-10-06T07:26:45+00:00","author":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/bb64053c3efbdc9d39bbb581db1af6bd"},"breadcrumb":{"@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/2015\/10\/06\/ieculen-60950-1-amendment-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.uk.tdk-lambda.com\/uk\/"},{"@type":"ListItem","position":2,"name":"IEC\/UL\/EN 60950-1 Amendment 2"}]},{"@type":"WebSite","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#website","url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/","name":"TDK-Lambda UK Blog","description":"TDK-Lambda EMEA Power Supply News","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.uk.tdk-lambda.com\/uk\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.uk.tdk-lambda.com\/uk\/#\/schema\/person\/bb64053c3efbdc9d39bbb581db1af6bd","name":"Dulcie","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2d49e58ebc4eae40264d7743a765c3e9cefedecc1f831cd9b207933081b116ba?s=96&d=mm&r=g","caption":"Dulcie"},"url":"https:\/\/blog.uk.tdk-lambda.com\/uk\/author\/dulcie\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/3113","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/comments?post=3113"}],"version-history":[{"count":0,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/posts\/3113\/revisions"}],"wp:attachment":[{"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/media?parent=3113"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/categories?post=3113"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.uk.tdk-lambda.com\/uk\/wp-json\/wp\/v2\/tags?post=3113"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}